Publication: Aug 09, 2021 Last updated: Aug 29, 2025

TPEs for ergonomically designed healthcare equipment


KRAIBURG TPE offers its THERMOLAST® M and THERMOLAST® K TPE compound solutions for improved ergonomics design advantages, to prevent injuries and safety hazards in healthcare equipment.

Ergonomic stressors, or the work needed to perform the tasks, are undoubtedly significantly impacting the productivity and well-being of healthcare workers.  

In a medical setting, healthcare workers are susceptible to ergonomic hazards. This involves from handling patients such as moving and transferring them about that may require bending, lifting, or a sudden force, to manual operation of medical equipment and furniture. Thus, maintaining a static posture (sitting or standing for an extended time), and other such awkward postures and repetitive or monotonous motions may result in musculoskeletal disorders or MSDs.  

There are ways to prevent MSDs, including adequate breaks or rest recovery periods, positioning strategies when lifting or bending, use of assist devices, and generally adapting the physiological demand of a task to suit a worker’s capacity.

In addition, ensuring that the equipment in use is ergonomically designed is also important to meet user capabilities and promote good work practices to prevent work-related risks.

For this purpose, new high-performance materials such as thermoplastics elastomers (TPEs) are widely used in the manufacture of healthcare devices and equipment to improve the ergonomics.  

KRAIBURG TPE, a global TPE manufacturer of a wide range of thermoplastic elastomer products and custom solutions for multiple industries, offers high quality and custom-engineered TPE compounds that feature exceptional elasticity, material processability and light weight advantages for healthcare equipment.

TPEs for safety and user-comfort

The application of KRAIBURG TPE’s TPE compounds in healthcare equipment delivers safety and efficiency, as well as optimized function and comfort for users. The TPE materials also give the necessary flexibility in the ergonomic application for the design of healthcare equipment.

The high-performance TPE compounds feature a soft-touch surface; chemical/scratch resistance; durability, and other desired properties that make them suitable for application in appliances and fittings. These include blood draw arm stands, footrest assemblies on chairs, transfer armchairs, phlebotomy chairs, and more.

Additionally, the pre-colorable TPE compounds are available with various color options that guarantee a consistent color quality worldwide.

Suitability for ergonomic designs

KRAIBURG TPE’s THERMOLAST® M series and THERMOLAST® K series of compounds are especially suited for applications that require ergonomic designs. Both consist of a wide range of hardness to cater to the different level of hardness required by customers.

They have good adhesion with PP, PC, ABS, PC/ABS, ASA, SAN, PET and PETG as well as PA; and can be processed via multi-component injection molding and co-extrusion processes.

These versatile compounds are compliant to international material safety standards. The THERMOLAST® M meets the requirement of VDI 2017, ISO 10993-5 standards and is listed in the Drug Master File. The THERMOLAST® K selected series complies with the relevant FDA-Code of Federal Regulations (CFR), Title 21, and standard EN 71/3 regulations as well as China GB standards.

KRAIBURG TPE Quick Facts
 

  • Founded in 2001 as an independent business unit of the KRAIBURG Group 
  • HQ & Production Site: Waldkraiburg / Germany
  • Regional HQ & Production site: Kuala Lumpur / Malaysia, Atlanta / USA
  • Products: Thermoplastic Elastomer Compounds
  • Brands: THERMOLAST®, COPEC®, HIPEX®, and For Tec E®
  • Markets: EMEA, APAC, Americas
  • Employees: 660

Download press release

In our media package you will find comprehensive information, graphics and pictures on the subject.

09.08.2021 MEDIA PACKAGE FOR TPEs for ergonomically designed healthcare equipment

Latest News

Reinforcing Functionality and Performance of Wrist Orthoses
15.05.2026 Reinforcing Functionality and Performance of Wrist Orthoses How can thermoplastic elastomers improve wrist orthoses design? KRAIBURG TPE THERMOLAST® H delivers soft-touch comfort, flexibility, reliable adhesion, and medical-grade compliance for durable and ergonomic support solutions. read more
KRAIBURG TPE will be exhibiting at PLAST 2026
12.05.2026 KRAIBURG TPE will be exhibiting at PLAST 2026 KRAIBURG TPE has traditionally maintained close business relationships with its Italian customers. Accordingly, PLAST 2026 in Milan is much more than just a must-attend event. As part of the three-year trade fair cycle, the TPE developer and manufacturer will focus in particular on the range of its product and service portfolio. read more
THERMOLAST® R TPE for Sustainable Robotic Applications
07.05.2026 THERMOLAST® R TPE for Sustainable Robotic Applications What material is suitable for robotic components that require durability, soft-touch surfaces, and sustainability? Discover how THERMOLAST® R thermoplastic elastomers from KRAIBURG TPE provide recycled content, strong adhesion to ABS, PC and PC/ABS, and design flexibility for robotics and consumer electronics applications. read more
Expanding its presence in the UK: KRAIBURG TPE UK Ltd. to have its own booth at Interplas 2026 for the first time
30.04.2026 Expanding its presence in the UK: KRAIBURG TPE UK Ltd. to have its own booth at Interplas 2026 for the first time KRAIBURG TPE, global competence leader in the field of thermoplastic elastomers, will be participating in Interplas 2026 under its own colors for the first time. This underscores the company’s long-term commitment to the British market. Following the founding of KRAIBURG TPE UK Ltd. in June 2024, this is another strategic step toward expanding the company’s own presence in the United Kingdom in a targeted manner. read more